Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Front Bioeng Biotechnol ; 12: 1351913, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476964

RESUMO

Introduction: Voluntary lateral weight shifting is essential for gait initiation. However, kinematic changes during voluntary lateral weight shifting remain unknown in people with low back pain (LBP). This study aims to explore the differences in kinematics and muscle activation when performing a voluntary lateral weight shifting task between patients with LBP and asymptomatic controls without pain. Methods: Twenty-eight participants volunteered in this study (14 in both the LBP group and the control group). The Sway Discrimination Apparatus (SwayDA) was used to generate a postural sway control task, mimicking lateral weight shifting movements when initiating gait. Kinematic parameters, including range of motion (ROM) and standard deviation of ROM (Std-ROM) of the lumbar spine, pelvis, and lower limb joints, were recorded using a motion capture system during lateral weight shifting. The electroactivity of the trunk and lower limb muscles was measured through surface electromyography using root mean square (RMS). The significant level was 0.05. An independent t-test was employed to compare kinematic parameters, and muscle activation between the LBP group and the control group. A paired-sample t-test, adjusted with Bonferroni correction (significant level of 0.025), was utilized to examine differences between the ipsilateral weight shifting towards side (dominant side) and the contralateral side. Results: The results of kinematic parameters showed significantly decreased ROM and std-ROM of the ipsilateral hip in the transverse plane (tROM = -2.059, p = 0.050; tstd-ROM = -2.670, p = 0.013), as well as decreased ROM of the ipsilateral knee in the coronal plane (t = -2.148, p = 0.042), in the LBP group compared to the control group. For the asymptomatic controls, significantly larger ROM and ROM-std were observed in the hip and knee joints on the ipsilateral side in contrast to the contralateral side (3.287 ≤ t ≤ 4.500, 0.001 ≤ p≤ 0.006), but no significant differences were found between the two sides in the LBP group. In addition, the LBP group showed significantly lower RMS of the biceps femoris than the control group (tRMS = -2.186, p = 0.044). Discussion: Patients with LBP showed a conservative postural control pattern, characterized by reduced ROM of ipsilateral joints and diminished activation of the biceps femoris. These findings suggested the importance of voluntary postural control assessment and intervention to maximize recovery.

2.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38492562

RESUMO

OBJECTIVES: It is uncertain if the evidence on improved long-term survival of total arterial coronary artery bypass grafting applies to female patients. This study aims to compare the long-term survival outcomes of using total arterial revascularization (TAR) versus at least 1 saphenous vein graft separately for men and women. METHODS: This retrospective analysis of the Australian and New Zealand Society of Cardiac-Thoracic Surgical Database had administrative linkage to the National Death Index. We identified all patients undergoing primary isolated coronary bypass from June 2001 to January 2020 inclusive. Following sex stratification, propensity score matching with 36 variables and Cox proportional hazard regression were used to facilitate adjusted comparisons. A Cox interaction-term analysis was performed to investigate the impact of sex on TAR survival benefit. The primary outcome was all-cause mortality. RESULTS: Of the 69 624 eligible patients receiving at least 2 grafts, 13 019 (18.7%) were female patients. Matching generated 14 951 male and 3530 female pairs. Compared to vein-dependent procedures, TAR was associated with significantly reduced incidence of long-term all-cause mortality for both male (hazard ratio, 0.86; 95% confidence interval, 0.81-0.91; P < 0.001) and female (hazard ratio, 0.82; 95% confidence interval, 0.73-0.91; P < 0.001) cohorts. Interaction-term analysis indicated no significant subgroup effect from sex (P = 0.573) on the survival advantage of TAR. The treatment effect provided by TAR remained significant across most sex-stratified disease subgroups. CONCLUSIONS: TAR, when compared to the use of at least 1 saphenous vein graft, provides comparable superior long-term survival outcomes in both females and males.


Assuntos
Doença da Artéria Coronariana , Caracteres Sexuais , Feminino , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Austrália , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Veia Safena/transplante
3.
Clin Rehabil ; : 2692155241229398, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38317586

RESUMO

OBJECTIVE: To review the effectiveness of different physical therapies for acute and sub-acute low back pain supported by evidence, and create clinical recommendations and expert consensus for physiotherapists on clinical prescriptions. DATA SOURCES: A systematic search was conducted in PubMed and the Cochrane Library for studies published within the previous 15 years. REVIEW METHODS: Systematic review and meta-analysis, randomized controlled trials assessing patients with acute and sub-acute low back pain were included. Two reviewers independently screened relevant studies using the same inclusion criteria. The Physiotherapy Evidence Database and the Assessment of Multiple Systematic Reviews tool were used to grade the quality assessment of randomized controlled trials and systematic reviews, respectively. The final recommendation grades were based on the consensus discussion results of the Delphi of 22 international experts. RESULTS: Twenty-one systematic reviews and 21 randomized controlled trials were included. Spinal manipulative therapy and low-level laser therapy are recommended for acute low back pain. Core stability exercise/motor control, spinal manipulative therapy, and massage can be used to treat sub-acute low back pain. CONCLUSIONS: The consensus statements provided medical staff with appliable recommendations of physical therapy for acute and sub-acute low back pain. This consensus statement will require regular updates after 5-10 years.

4.
Sensors (Basel) ; 23(21)2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37960555

RESUMO

The ability of the lumbar extensor muscles to accurately control static and dynamic forces is important during daily activities such as lifting. Lumbar extensor force control is impaired in low-back pain patients and may therefore explain the variances in lifting kinematics. Thirty-three chronic low-back pain participants were instructed to lift weight using a self-selected technique. Participants also performed an isometric lumbar extension task where they increased and decreased their lumbar extensor force output to match a variable target force within 20-50% lumbar extensor maximal voluntary contraction. Lifting trunk and lower limb range of motion and angular velocity variables derived from phase plane analysis in all planes were calculated. Lumbar extensor force control was analyzed by calculating the Root-Mean-Square Error (RMSE) between the participants' force and the target force during the increasing (RMSEA), decreasing (RMSED) force portions and for the overall force error (RMSET) of the test. The relationship between lifting kinematics and RMSE variables was analyzed using multiple linear regression. Knee angular velocity in the sagittal and coronal planes were positively associated with RMSEA (R2 = 0.10, ß = 0.35, p = 0.046 and R2 = 0.21, ß = 0.48, p = 0.004, respectively). Impaired lumbar extensor force control is associated with increased multiplanar knee movement velocity during lifting. The study findings suggest a potential relationship between lumbar and lower limb neuromuscular function in people with chronic low-back pain.


Assuntos
Remoção , Dor Lombar , Humanos , Joelho , Articulação do Joelho/fisiologia , Extremidade Inferior , Fenômenos Biomecânicos
5.
BMJ Open ; 13(7): e067914, 2023 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-37451709

RESUMO

INTRODUCTION: There is no consistency in current practice pertaining to the prescription and progression of upper limb resistance exercise following cardiac surgery via median sternotomy. The aim of this study is to investigate whether less restrictive sternal precautions with the addition of early-supervised resistance training exercise improves upper limb function and facilitates recovery following median sternotomy. METHODS AND ANALYSIS: This is double-blind randomised controlled trial, with parallel group, concealed allocation, blinding of patients and assessors, and intention-to-treat analysis. 240 adult participants who had median sternotomy from eight hospitals in Malaysia will be recruited. Sample size calculations were based on the unsupported upper limb test. All participants will be randomised to receive either standard or early supervised incremental resistance training. The primary outcomes are upper limb function and pain. The secondary outcomes will be functional capacity, multidomain recovery (physical and psychological), length of hospital stay, incidence of respiratory complications and quality of life. Descriptive statistics will be used to summarise data. Data will be analysed using the intention-to-treat principle. The primary hypothesis will be examined by evaluating the change from baseline to the 4-week postoperative time point in the intervention arm compared with the usual care arm. For all tests to be conducted, a p value of <0.05 (two tailed) will be considered statistically significant, and CIs will be reported. The trial is currently recruiting participants. ETHICS AND DISSEMINATION: The study was approved by a central ethical committee as well as the local Research Ethics Boards of the participating sites (UKM:JEP-2019-654; Ministry of Health: NMMR-50763; National Heart Centre: IJNREC/501/2021). Approval to start was given prior to the recruitment of participants commencing at any sites. Process evaluation findings will be published in peer-reviewed journals and presented at relevant academic conferences. TRIAL REGISTRATION NUMBER: International Standard Randomised Controlled Trials Number (ISRCTN17842822).


Assuntos
Procedimentos Cirúrgicos Cardíacos , Esternotomia , Adulto , Humanos , Esternotomia/efeitos adversos , Qualidade de Vida , Método Duplo-Cego , Tempo de Internação , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
6.
Acta Anaesthesiol Scand ; 67(10): 1294-1305, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37403236

RESUMO

Traditional risk factors used for predicting poor postoperative recovery have focused on postoperative complications, adverse symptoms (nausea, pain), length of hospital stay, and patient quality of life. Despite these being traditional performance indicators of patient postoperative "status," they may not fully define the multidimensional nature of patient recovery. The definition of postoperative recovery is thus evolving to include patient-reported outcomes that are important to the patient. Previous reviews have focused on risk factors for the above traditional outcomes after major surgery. Yet, there remains a need for further study of risk factors predicting multidimensional patient-focused recovery, and investigation beyond the immediate postoperative period after patients are discharged from the hospital. This review aimed to appraise the current literature identifying risk factors for multidimensional patient recovery. METHODS: A systematic review without meta-analysis was performed to qualitatively summarize preoperative risk factors for multidimensional recovery 4-6 weeks after major surgery (PROSPERO, CRD42022321626). We reviewed three electronic databases between January 2012 and April 2022. The primary outcome was risk factors for multidimensional recovery at 4-6 weeks. A GRADE quality appraisal and a risk of bias assessment were completed. RESULTS: In total, 5150 studies were identified, after which 1506 duplicates were removed. After the primary and secondary screening, nine articles were included in the final review. Interrater agreements between the two assessors for the primary and secondary screening process were 86% (k = 0.47) and 94% (k = 0.70), respectively. Factors associated with poor recovery were found to include ASA grade, recovery tool baseline score, physical function, number of co-morbidities, previous surgery, and psychological well-being. Mixed results were reported for age, BMI, and preoperative pain. Due to the observational nature, heterogeneity, multiple definitions of recovery, and moderate risk of bias of the primary studies, the quality of evidence was rated from very low to low. CONCLUSION: Our review found that there were few studies assessing preoperative risk factors as predictors for poor postoperative multidimensional recovery. This confirms the need for higher quality studies assessing risk for poor recovery, ideally with a consistent and multi-dimensional definition of recovery.

7.
Sensors (Basel) ; 23(11)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37299827

RESUMO

BACKGROUND: The COVID-19 pandemic has accelerated the demand for utilising telehealth as a major mode of healthcare delivery, with increasing interest in the use of tele-platforms for remote patient assessment. In this context, the use of smartphone technology to measure squat performance in people with and without femoroacetabular impingement (FAI) syndrome has not been reported yet. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient's device and measure their squat performance in real time using the smartphone inertial sensors. The aim of this study was to investigate the association and test-retest reliability of the TelePhysio app in measuring postural sway performance during a double-leg (DLS) and single-leg (SLS) squat task. In addition, the study investigated the ability of TelePhysio to detect differences in DLS and SLS performance between people with FAI and without hip pain. METHODS: A total of 30 healthy (nfemales = 12) young adults and 10 adults (nfemales = 2) with diagnosed FAI syndrome participated in the study. Healthy participants performed DLS and SLS on force plates in our laboratory, and remotely in their homes using the TelePhysio smartphone application. Sway measurements were compared using the centre of pressure (CoP) and smartphone inertial sensor data. A total of 10 participants with FAI (nfemales = 2) performed the squat assessments remotely. Four sway measurements in each axis (x, y, and z) were computed from the TelePhysio inertial sensors: (1) average acceleration magnitude from the mean (aam), (2) root-mean-square acceleration (rms), (3) range acceleration (r), and (4) approximate entropy (apen), with lower values indicating that the movement is more regular, repetitive, and predictable. Differences in TelePhysio squat sway data were compared between DLS and SLS, and between healthy and FAI adults, using analysis of variance with significance set at 0.05. RESULTS: The TelePhysio aam measurements on the x- and y-axes had significant large correlations with the CoP measurements (r = 0.56 and r = 0.71, respectively). The TelePhysio aam measurements demonstrated moderate to substantial between-session reliability values of 0.73 (95% CI 0.62-0.81), 0.85 (95% CI 0.79-0.91), and 0.73 (95% CI 0.62-0.82) for aamx, aamy, and aamz, respectively. The DLS of the FAI participants showed significantly lower aam and apen values in the medio-lateral direction compared to the healthy DLS, healthy SLS, and FAI SLS groups (aam = 0.13, 0.19, 0.29, and 0.29, respectively; and apen = 0.33, 0.45, 0.52, and 0.48, respectively). In the anterior-posterior direction, healthy DLS showed significantly greater aam values compared to the healthy SLS, FAI DLS, and FAI SLS groups (1.26, 0.61, 0.68, and 0.35, respectively). CONCLUSIONS: The TelePhysio app is a valid and reliable method of measuring postural control during DLS and SLS tasks. The application is capable of distinguishing performance levels between DLS and SLS tasks, and between healthy and FAI young adults. The DLS task is sufficient to distinguish the level of performance between healthy and FAI adults. This study validates the use of smartphone technology as a tele-assessment clinical tool for remote squat assessment.


Assuntos
COVID-19 , Impacto Femoroacetabular , Adulto Jovem , Humanos , Impacto Femoroacetabular/diagnóstico , Smartphone , Reprodutibilidade dos Testes , Perna (Membro) , Pandemias , Dor , Equilíbrio Postural
8.
J Aging Phys Act ; 31(6): 948-955, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37263592

RESUMO

This prospective study aimed to determine which specific mobility tests were the most accurate for predicting falls in physically active older adults living in the community. Seventy-nine physically active older adults who met the American College of Sports Medicine physical activity guidelines volunteered. Participants were assessed and followed up for 12 months. Mobility assessments included the 30-s sit-to-stand test, five times sit-to-stand test, single-task timed-up-and-go test (TUG), motor dual-task TUG (Mot-TUG), and cognitive dual-task TUG (Cog-TUG). Mot-TUG and Cog-TUG performances were moderately correlated with number of falls (r = .359, p < .01 and r = .372, p < .01, respectively). When Mot-TUG, Cog-TUG, or Age were included as fall predictors, discrimination scores represented by the area under the receiver operating characteristic curve (AUC) were AUC (Mot-TUG) = 0.843 (p < .01), AUC (Cog-TUG) = 0.856 (p < .01), and AUC (Age) = 0.734 (p < .05). The cutoff point for Cog-TUG was 10.98 s, with test sensitivity of 1.00 and specificity of 0.66. Fall predictors for different populations may be based on different test methods. Here, the dual-task TUG test more accurately predicted falls in older adults who met American College of Sports Medicine's physical activity guidelines.


Assuntos
Vida Independente , Equilíbrio Postural , Humanos , Idoso , Estudos Prospectivos , Avaliação Geriátrica/métodos , Estudos de Tempo e Movimento
9.
Crit Care Med ; 51(2): e24-e36, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36661463

RESUMO

OBJECTIVE: Significant variations exist in the use of respiratory muscle ultrasound in intensive care with no society-level consensus on the optimal methodology. This systematic review aims to evaluate, synthesize, and compare the clinimetric properties of different image acquisition and analysis methodologies. DATA SOURCES: Systematic search of five databases up to November 24, 2021. STUDY SELECTION: Studies were included if they enrolled at least 50 adult ICU patients, reported respiratory muscle (diaphragm or intercostal) ultrasound measuring either echotexture, muscle thickness, thickening fraction, or excursion, and evaluated at least one clinimetric property. Two independent reviewers assessed titles, abstracts, and full text against eligibility. DATA EXTRACTION: Study demographics, ultrasound methodologies, and clinimetric data. DATA SYNTHESIS: Sixty studies, including 5,025 patients, were included with 39 studies contributing to meta-analyses. Most commonly measured was diaphragm thickness (DT) or diaphragm thickening fraction (DTF) using a linear transducer in B-mode, or diaphragm excursion (DE) using a curvilinear transducer in M-mode. There are significant variations in imaging methodology and acquisition across all studies. Inter- and intrarater measurement reliabilities were generally excellent, with the highest reliability reported for DT (ICC, 0.98; 95% CI, 0.94-0.99). Pooled data demonstrated acceptable to excellent accuracy for DT, DTF, and DE to predicting weaning outcome after 48 to 72 hours postextubation (DTF AUC, 0.79; 95% CI, 0.73-0.85). DT imaging was responsive to change over time. Only three eligible studies were available for intercostal muscles. Intercostal thickening fraction was shown to have excellent accuracy of predicting weaning outcome after 48-hour postextubation (AUC, 0.84; 95% CI, 0.78-0.91). CONCLUSIONS: Diaphragm muscle ultrasound is reliable, valid, and responsive in ICU patients, but significant variation exists in the imaging acquisition and analysis methodologies. Future work should focus on developing standardized protocols for ultrasound imaging and consider further research into the role of intercostal muscle imaging.


Assuntos
Diafragma , Desmame do Respirador , Adulto , Humanos , Desmame do Respirador/métodos , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Diafragma/diagnóstico por imagem , Cuidados Críticos
10.
Front Neurosci ; 17: 1285747, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38235390

RESUMO

Introduction: Low back pain (LBP) is associated with altered somatosensory perception, which is involved in both involuntary and voluntary control of posture. Currently, there is a lack of methods and tools for assessing somatosensory acuity in patients with LBP. The purpose of this study was (1) to assess the reliability of the sway discrimination apparatus (SwayDA) (2) to evaluate the differences in somatosensory acuity between patients with LBP and pain-free individuals, and (3) to examine relationships between somatosensory acuity, severity of LBP, and mobility in patients with LBP. Methods: Twenty participants (10 patients with LBP and 10 matched asymptomatic controls) were recruited in a test-retest reliability test. Another 56 participants were recruited for this study with 28 individuals presenting with LBP and a further twenty-eight being asymptomatic. The SwayDA was custom-built to measure somatosensory perception during voluntary anterior-posterior (SwayDA-AP), medial-lateral to the dominant side (SwayDA-ML-D), and non-dominant side (SwayDA-ML-ND) postural sway control. Participants also completed mobility tests, including 10 times and 1-min sit-to-stand tests (10-STS, 1 m-STS). The area under the receiver operating characteristic curve (AUC) was calculated to quantify somatosensory acuity in discriminating different voluntary postural sway extents. Results: The ICC (2.1) for the SwayDA-AP, SwayDA-ML-D, and SwayDA-ML-ND were 0.741, 0.717, and 0.805 with MDC95 0.071, 0.043, and 0.050. Patients with LBP demonstrated significantly lower SwayDA scores (tSwayDA-AP = -2.142, p = 0.037; tSwayDA-ML-D = -2.266, p = 0.027) than asymptomatic controls. The AUC values of the SwayDA-AP test were significantly correlated with ODI (rSwayDA-AP-ODI = -0.391, p = 0.039). Performances on the 1 m-STS and the 10-STS were significantly correlated with the AUC scores from all the SwayDA tests (-0.513 ≤ r ≤ 0.441, all p < 0.05). Discussion: The SwayDA tests evaluated showed acceptable reliability in assessing somatosensory acuity during voluntary postural sway. Somatosensory acuity was diminished in patients with LBP compared to asymptomatic controls. In patients with LBP, lower somatosensory acuity was associated with increased LBP-related disability. Future research could focus on investigating the factors contributing to the decreased somatosensory perception and mobility in individuals with LBP.

11.
Sensors (Basel) ; 22(21)2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36365852

RESUMO

BACKGROUND: Tele-health has become a major mode of delivery in patient care, with increasing interest in the use of tele-platforms for remote patient assessment. The use of smartphone technology to measure hip range of motion has been reported previously, with good to excellent validity and reliability. However, these smartphone applications did not provide real-time tele-assessment functionality. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient's device and measure their hip range of motion in real time. The aim of this study was to investigate the concurrent validity and between-sessions reliability of the TelePhysio app. In addition, the study investigated the concurrent validity, between-sessions, and inter-rater reliability of a second tele-assessment approach using video analysis. METHODS: Fifteen participants (nfemales = 6) were assessed in our laboratory (session 1) and at their home (session 2). We assessed maximum voluntary active hip flexion in supine and hip internal and external rotation, in both prone and sitting positions. TelePhysio and video analysis were validated against the laboratory's 3-dimensional motion capture system in session 1, and evaluated for between-sessions reliability in session 2. Video analysis inter-rater reliability was assessed by comparing the analysis of two raters in session 2. RESULTS: The TelePhysio app demonstrated high concurrent validity against the 3D motion capture system (ICCs 0.63-0.83) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.48, p = 0.99). The video analysis demonstrated almost perfect concurrent validity against the 3D motion capture system (ICCs 0.85-0.94) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.44, p = 0.01). The TelePhysio and video analysis demonstrated good between-sessions reliability for hip external rotation and hip flexion, ICC 0.64 and 0.62, respectively. The between-sessions reliability of hip internal and external rotation for both TelePhysio and video analysis was fair (ICCs 0.36-0.63). Inter-rater reliability ICCs for the video analysis were 0.59 for hip flexion and 0.87-0.95 for the hip rotation range. CONCLUSIONS: Both tele-assessment approaches, using either a smartphone application or video analysis, demonstrate good to excellent concurrent validity, and moderate to substantial between-sessions reliability in measuring hip rotation and flexion range of motion, but less in internal hip rotation in the prone position. Thus, it is recommended that the seated position be used when assessing hip internal rotation. The use of a smartphone to remotely assess hip range of motion is an appropriate, effective, and low-cost alternative to the face-to-face assessments. This method provides a simple, cost effective, and accessible patient assessment tool with no additional cost. This study validates the use of smartphone technology as a tele-assessment tool for remote hip range of motion assessment.


Assuntos
Aplicativos Móveis , Smartphone , Humanos , Reprodutibilidade dos Testes , Amplitude de Movimento Articular , Movimento
12.
J Am Coll Cardiol ; 80(19): 1833-1843, 2022 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-36328694

RESUMO

Approximately 95% of patients of any age undergoing contemporary, coronary bypass surgery will receive at least 1 saphenous vein graft (SVG). It is recognized that SVG will develop progressive and accelerated atherosclerosis, resulting in a stenosis, and in occlusion that occurs in 50% by 10 years postoperatively. For arterial conduits, there is little evidence of progressive failure as for SVG. Could avoidance of SVG (total arterial revascularization [TAR]) lead to a different late (>5 year) survival? A literature review of 23 studies (N = 100,314 matched patients) at a mean 8.8 years postoperative found reduced all-cause mortality for TAR (HR: 0.77; 95% CI: 0.71-0.84; P < 0.001). An expanded analysis with a new unpublished data set (N = 63,288 matched patients) was combined with the literature review (N = 127,565). It found reduced all-cause mortality for TAR (HR: 0.78; 95% CI: 0.72-0.85; P < 0.001). Additional Bayesian analysis found a very high probability of a TAR-associated reduction all-cause mortality.


Assuntos
Ponte de Artéria Coronária , Veia Safena , Humanos , Veia Safena/transplante , Teorema de Bayes , Resultado do Tratamento , Ponte de Artéria Coronária/métodos , Artérias
13.
Front Cardiovasc Med ; 9: 841453, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36093135

RESUMO

Background: Sit-To-Stand (STS) tests are reported as feasible alternatives for the assessment of functional fitness but the reliability of these tests in people with coronary artery disease (CAD) has not been reported. This study explored the test-retest reliability, convergent and known-groups validity of the five times, 30-sec and 1-min sit-to-stand test (FTSTS test, 30-s STS test and 1-min STS test respectively) in patients with CAD. The feasibility of applying these tests to distinguish the level of risk for cardiovascular events in CAD patients was also investigated. Methods: Patients with stable CAD performed a 6MWT and 3 STS tests in random order on the same day. Receiver operating characteristic (ROC) curve analyses were conducted using STS test data to differentiate patients with low or high risk of cardiovascular events based on the risk level determined by distance covered in the 6MWT as > or ≤ 419 m. Thirty patients repeated the 3 STS tests on the following day. Results: 112 subjects with diagnoses of atherosclerosis or post-percutaneous coronary intervention, or post-acute myocardial infarction (post-AMI) participated in the validity analysis. All 3 STS tests demonstrated moderate and significant correlation with the 6MWT (coefficient values r for the FTSTS, 30-s STS and 1-min STS tests were-0.53, 0.57 and 0.55 respectively). Correlations between left ventricular ejection fraction (LVEF) and all STS tests and between 6MWT and LVEF were only weak (r values ranged from 0.27 to 0.31). Subgroup analysis showed participants in the post-AMI group performed worse in all tests compared to non-myocardial infarction (non-MI) group. The area under the curve (AUC) was 0.80 for FTSTS (sensitivity: 75.0%, specificity: 73.8%, optimal cut-off: >11.7 sec), and the AUC, sensitivity, specificity and optimal cut-off for 30-s STS and 1-min STS test were 0.83, 75.0%, 76.2%, ≤ 12 repetitions and 0.80, 71.4%, 73.8%, ≤ 23 repetitions respectively. The intraclass correlation coefficients (ICC) for repeated measurements of the FTSTS, 30-s STS and 1-min STS tests were 0.96, 0.95 and 0.96 respectively, with the minimal detectable change (MDC95) computed to be 1.1 sec 1.8 repetitions and 3.9 repetitions respectively. Conclusions: All STS tests demonstrated good test-retest reliability, convergent and known-groups validity. STS tests may discriminate low from high levels of risk for a cardiovascular event in patients with CAD.

14.
Phys Ther ; 102(7)2022 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-35551413

RESUMO

OBJECTIVE: The purpose of this study was to determine the safety and feasibility of subacute upper limb resistance exercise on sternal micromotion and pain and the reliability of sternal ultrasound assessment following cardiac surgery via median sternotomy. METHODS: This experimental study used a pretest-posttest design to investigate the effects of upper limb resistance exercise on the sternum in patients following their first cardiac surgery via median sternotomy. Six bilateral upper limb machine-based exercises were commenced at a base resistance of 20 lb (9 kg) and progressed for each participant. Sternal micromotion was assessed using ultrasound at the mid and lower sternum at 2, 8, and 14 weeks postsurgery. Intrarater and interrater reliability was calculated using intraclass correlation coefficients (ICCs). Participant-reported pain was recorded at rest and with each exercise using a visual analogue scale. RESULTS: Sixteen adults (n = 15 males; 71.3 [SD = 6.2] years of age) consented to participate. Twelve participants completed the study, 2 withdrew prior to the 8-week assessment, and 2 assessments were not completed at 14 weeks due to assessor unavailability. The highest median micromotion at the sternal edges was observed during the bicep curl (median = 1.33 mm; range = -0.8 to 2.0 mm) in the lateral direction and the shoulder pulldown (median = 0.65 mm; range = -0.8 to 1.6 mm) in the anterior-posterior direction. Furthermore, participants reported no increase in pain when performing any of the 6 upper limb exercises. Interrater reliability was moderate to good for both lateral-posterior (ICC = 0.73; 95% CI = 0.58 to 0.83) and anterior-posterior micromotion (ICC = 0.83; 95% CI = 0.73 to 0.89) of the sternal edges. CONCLUSION: Bilateral upper limb resistance exercises performed on cam-based machines do not result in sternal micromotion exceeding 2.0 mm or an increase in participant-reported pain. IMPACT: Upper limb resistance training commenced as early as 2 weeks following cardiac surgery via median sternotomy and performed within the safe limits of pain and sternal micromotion appears to be safe and may accelerate postoperative recovery rather than muscular deconditioning.


Assuntos
Treinamento de Força , Esternotomia , Estudos de Viabilidade , Humanos , Masculino , Dor/etiologia , Reprodutibilidade dos Testes
15.
Front Cardiovasc Med ; 9: 853376, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35463794

RESUMO

Objective: The aim of this study was to assess the efficacy of a 6-week cardiac rehabilitation (CR) program designed for patients with coronary artery disease (CAD) after percutaneous coronary intervention (PCI) that involved an online supervised exercise program that they could access during COVID-19. Methods: One hundred patients were randomly allocated into control group (CG) and supervision group (SG). CG accepted conventional health education with a home exercise program booklet delivered before discharge, SG had an additional home-based online supervised exercise program (HOSEP). Questionnaires, motor function and lipid profile were administered at baseline. Questionnaires included the Godin-Shephard Leisure-Time Physical Activity questionnaire (GSLTPAQ) and Bandura's Exercise Self-efficacy (ESE). Motor function included: 6-min walk test (6 MWT), timed up and go test (TUG), 30-s sit to stand (30-s STS), and Hand Grip Strength (HG). Lipid profile included: low-density lipoprotein (LDL), high-density lipoprotein (HDL), total cholesterol (TC) and triglycerides (TG). The questionnaires were re-administered after 2-weeks, all tests were re-evaluated after 6-weeks. Results: the questionnaire results showed that scores on GSLTPAQ and ESE were significantly improved in the SG. The changes in GSLTPAQ scores from baseline to 2- and 6-weeks in the SG were significantly higher than in the CG (2-week: 6.9 ± 13.0 for SG and 0.2 ± 10.2 for CG, p = 0.005; 6-week: 9.4 ± 18.1 for SG and 0.2 ± 11.8 for CG, p = 0.003). in terms of motor function, both the CG and SG improved TUG and 6 MWT performance, with the 6 MWT improvement being significantly greater in the SG than CG (43.7 ± 39.2 m for SG and 16.6 ± 39.1 m for CG, p = 0.001). Improvement in the 30-s STS was significantly greater in the SG than CG (2.4 ± 3.6 repetitions for SG and 0.4 ± 3.5 repetitions for CG, p = 0.007). the lipid profile level significantly improved over baseline in both SG and CG after 6-week intervention, and these changes were not statistically different between groups. Conclusion: This pilot randomized control study demonstrated that a 6-week HOSEP, when added to education delivered pre-hospital discharge for CAD patients following PCI, was beneficial with respect to exercise self-efficacy, exercise behavior, motor function and lipid profile. Supervised exercise programs delivered online in addition to education providing effective and accessible CR during COVID-19.

16.
Front Nutr ; 9: 831109, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35419397

RESUMO

Mediterranean Diet management for people with cardiovascular disease (CVD) or CVD risk is supported by evidence. However, there is no valid Chinese language instrument for the measurement of adherence to this diet. The objective of this study was to generate a Chinese version of the Mediterranean Diet Scale (MDS-Chinese) and to validate a self-administered version with Chinese participants with CVD or CVD risk. The MDS-Chinese was created by translation and cultural adaptation and tested for psychometric properties. A panel of 10 experts in the field, who evaluated the MDS-Chinese content, showed that the content validity index ranged from 0.88 to 1.00. Sixteen native Chinese speakers with CVD or CVD risk evaluated the clarity of the MDS-Chinese, and the resulting instruction and items clarity scores ranged from 9.2 to 10.0. A total of 326 participants completed the MDS-Chinese and a Chinese version of the Coronary Artery Disease Education Questionnaire-Short Version (CADE-Q SV). Analysis indicated that the MDS-Chinese has 4 factors, and the Pearson's correlation between the MDS-Chinese and CADE-Q SV was 0.73. Fifty randomly selected participants completed the MDS-Chinese again with a 1-week interval to assess reliability. Internal consistency was acceptable (Cronbach's α was 0.62) and the inter-class correlation reliability coefficients (ICC) for each item ranged from 0.73 to 0.88. This study showed that the MDS-Chinese has acceptable reliability and validity for use among those in the Chinese population with CVD or CVD risk. Given that diet is one of the key secondary prevention strategies for management in cardiac rehabilitation, the MDS-Chinese instrument may be a useful and convenient tool for use with those in the Chinese population with CVD or with high risk of CVD, to monitor the level of Mediterranean diet (MD) adherence, information which is important for clinical practice. In addition, the establishment of the MDS-Chinese gives a fundamental tool for diet-related CVD research in the Chinese population. Moreover, employment of the MDS-Chinese in the Chinese community may improve awareness of the importance of a healthy diet in CVD prevention and management. Clinical Trial Registration: http://www.chictr.org.cn/enIndex.aspx, identifier: ChiCTR2000032810.

17.
Med Probl Perform Art ; 37(1): 30-36, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35234803

RESUMO

BACKGROUND: Neck pain is common in dancers, especially female dancers, and the injury pattern varies in different genres of dance. Among dancesport performers, intensive neck left rotation is required in female International Standard dancers, but it is unknown whether neck pain is associated with neck rotation range of motion and proprioception. OBJECTIVES: To explore the associations between neck pain, cervical rotation range of motion, and proprioception in female International Standard dancers. METHODS: Twelve dancers with dance-related neck pain (age 19.9±1.9 yrs) volunteered, matched with 12 not reporting neck pain (age 22.2±2.4 yrs). A 100-mm visual analog scale (VAS) was used to record neck pain. Active rotation range of motion (AROM) of the cervical spine was measured using a tape measure. A cervical rotation reposition test that used a head-mounted laser projector on a linear scale was employed to measure the cervical spine proprioception, and the absolute error (AE) and variable error (VE) were calculated as proprioceptive acuity scores. RESULTS: Nine of 12 participants in the group with neck pain declared left side pain, with 2 reporting pain on both sides. The group with neck pain had significantly lower left rotation AROM (p<0.05). For proprioceptive acuity, mixed model ANOVA only showed that repositioning of the right side of the neck is more accurate and consistent than that of the left (both AE and VE p<0.05). Linear regression analysis indicated that left rotation AROM was significantly influenced by left neck pain (t=3.061, p=0.006, adjusted R2 = 0.267, and Durbin-Watson value = 1.776). CONCLUSIONS: Most participants in the group with neck pain showed left side pain, associated with decreased left rotation AROM. Early screening on cervical rotation mobility may be necessary to reduce future dance-related injury after the onset of neck pain. Proprioceptive acuity of the left side neck was significantly impaired compared with that of the right, indicating future proprioceptive intervention on the left side neck.


Assuntos
Cervicalgia , Propriocepção , Adolescente , Adulto , Estudos de Casos e Controles , Vértebras Cervicais , Feminino , Humanos , Amplitude de Movimento Articular , Adulto Jovem
18.
Physiotherapy ; 114: 16-29, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35091326

RESUMO

OBJECTIVE: To evaluate the effectiveness of stretching exercises for pain relief in individuals with knee osteoarthritis (KOA). DATA SOURCES: Nine databases (PubMed, Embase, Cochrane Library, Web of Science, EBSCO, PEDro, CNKI, WanFang and CQVIP) were searched in December 2020. STUDY SELECTION: Randomised controlled trials (RCTs) involving stretching exercises conducted on individuals with KOA were included. STUDY APPRAISAL AND SYNTHESIS METHODS: Literature quality and risk of bias were assessed with the Physiotherapy Evidence Database scale and Cochrane Collaboration tool, respectively. Data were extracted by two independent assessors using a standardised form. The weighted mean difference (WMD) and standard deviations (SD) with 95% confidence intervals (CI) were analysed. RESULTS: In total, 373 studies were screened, with a final selection of 19 RCTs involving 1250 participants; of these, 18 RCTs were included in the final meta-analysis. When stretching exercises were used alone, the reduction of pain using a visual analogue scale was both significant and clinically meaningful (WMD 1.86; 95% CI 1.31 to 2.41). When stretching exercises were used in combination with other exercises, the pain reduction was still significant but its clinical significance became questionable (WMD 1.31; 95% CI 0.77 to 1.85). LIMITATIONS: The sample size of studies using stretching exercises alone was small, and some of the pooled studies were heterogeneous. CONCLUSIONS: Stretching exercises can be useful in pain management in individuals with KOA, especially when used alone. Programmes involving both stretching exercises and other exercises may improve function but may not achieve a clinically effective reduction in pain. Systematic review registration number Research Registry (No. reviewregistry813).


Assuntos
Osteoartrite do Joelho , Exercício Físico , Terapia por Exercício , Humanos , Articulação do Joelho , Dor
19.
Eur J Nutr ; 61(4): 2183-2199, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35084574

RESUMO

PURPOSE: The objective of this study was to compare the effects of 12 weeks of resistance training combined with either 5:2 intermittent fasting or continuous energy restriction on body composition, muscle size and quality, and upper and lower body strength. METHODS: Untrained individuals undertook 12 weeks of resistance training plus either continuous energy restriction [20% daily energy restriction (CERT)] or 5:2 intermittent fasting [~ 70% energy restriction 2 days/week, euenergetic consumption 5 days/week (IFT)], with both groups prescribed a mean of ≥ 1.4 g of protein per kilogram of body weight per day. Participants completed 2 supervised resistance and 1 unsupervised aerobic/resistance training combination session per week. Changes in lean body mass (LBM), thigh muscle size and quality, strength and dietary intake were assessed. RESULTS: Thirty-four participants completed the study (CERT = 17, IFT = 17). LBM was significantly increased (+ 3.7%, p < 0.001) and body weight (- 4.6%, p < 0.001) and fat (- 24.1%, p < 0.001) were significantly reduced with no significant difference between groups, though results differed by sex. Both groups showed improvements in thigh muscle size and quality, and reduced intramuscular and subcutaneous fat assessed by ultrasonography and peripheral quantitative computed tomography (pQCT), respectively. The CERT group demonstrated a significant increase in muscle surface area assessed by pQCT compared to the IFT group. Similar gains in upper and lower body strength and muscular endurance were observed between groups. CONCLUSION: When combined with resistance training and moderate protein intake, continuous energy restriction and 5:2 intermittent fasting resulted in similar improvements in body composition, muscle quality, and strength. ACTRN: ACTRN12620000920998, September 2020, retrospectively registered.


Assuntos
Treinamento de Força , Composição Corporal/fisiologia , Peso Corporal , Jejum/fisiologia , Humanos , Força Muscular/fisiologia
20.
Ultrasound Med Biol ; 48(2): 170-179, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34740496

RESUMO

The aim in this systematic review was to determine the effect of point-of-care ultrasound (POCUS) on the clinical decision-making process and patient outcomes in adults admitted to the general medicine ward. A comprehensive search was performed in MEDLINE (Ovid), EMBASE (Ovid), PubMed, the Cochrane Library, ClinicalTrials.gov, Scopus, LILACS and Cinahl. Articles had to fulfill the inclusion criteria of randomised or non-randomised studies assessing the impact of POCUS on the diagnosis, management, length of hospital stay or mortality of patients admitted to the internal medicine ward. Six studies were included involving a total of 1836 patients. The influence of POCUS on the diagnosis was reported as a change in the main diagnosis or the addition of a relevant diagnosis in up to 18% and 24% of the cases, respectively. Impact on the management plan was reported in 37% to 52.1% of the participants. Three studies documented the impact of POCUS on the length of stay. Two of them reported no difference between groups, and the other reported a significant reduction of 1 d of the hospital stay. In conclusion, POCUS appears to have positive effects on the clinical decision-making process with impacts on optimal patient management and possible reduction in the hospital length of stay.


Assuntos
Pacientes Internados , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Humanos , Tempo de Internação , Testes Imediatos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...